01.07: BS7671:2018+A3:2024 Compliance (Bi-directional device check)
01.07: Default separate CPC size option for armour and non armour cables
01.07: Further adiabatic checks based on PD CLC/TR 50480:2011 UK NA (Webinar)
01.07: Bunched cables grouping factor calculation when different cable sizes exist in the group
01.07: New Revit EOM Browser
01.07: Revit Sync: On demand set Revit IDs Assignment. This will allow you to use an existing EOM model and link it with the Revit elemets
01.08: Generic inverter element for DC/AC conversion
01.08: New Manual Selectivity Study Functionality
01.08: Board way labels editor
01.08: Network Multi sources: Ability to calculate and generate reports for multiple active networks
01.07: Ability to define the zero sequence (Z0) impedance for the main transformer supply
01.07: Favourites symbol category in CAD plan add-on
01.07: EOM Revit live sync improvements
01.07: EOM Revit ATS connection improvements
01.07: Arc flash 2I Protection setting for ABB EMAX 2 Ekip Touch and Hi-Touch devices
01.07: Warnings can be exported to excel
01.07: Ability to export the circuit details and arc flash pages to excel
01.07: Included the boards location, the Zs and Max. Zs figures in the circuit details page
01.07: When typing 'k' in the watts text box in the circuit editor it will mutiply the inputed number by 1000
01.07: Extra functionality for managing the UK forms certificates registry
01.07: Replace description function added in the find circuit tool
01.08: Switcboard supplies selection directly from the circuit editor
01.08: Ability to hide the O/L rating from motor starter component
01.08: Custom part number - BoQ costing code can be defined for final circuit elements
01.08: New simple warning: If the voltage exceeds 1000V, ensure that all equipment is rated for at least 1500V to guarantee safe operation
01.08: Solar PV String properties are presented on the Properties area
01.08: Excel based reports: new &c_CPD_BiDir code (Yes/No) for board schedules when the protective device is Bidirectional
01.08: Excel based reports: new &c_Cg_factor code for the Grouping (Cg) correction factor
01.08: Ability to define any number of extra cores/cables
01.08: Relay curves tolerance option
01.08: Main transformer supply source inrush current visualisation
01.08: Ability to set an extra logo for the report's main cover page
01.08: Adiabatic lines for separate CPC and armour withstand checks in the selectivity study
01.08: Illustration of the earth fault disconnection time in the selectivity study
01.08: Incomer SPD can be positioned before or after the incomer devices
01.09: Improvements to the Solar PV inverter element for compliance with BS 7671:2024 Reg. 712.433.104
01.10: Ability to select circuits in the circuit details page based on contained text in the circuit's full description
01.06: Hager ACBs HW+ HW2 and HW4
01.06: Hager New RCBOs
01.06: Hager New AFDD RCBO
01.06: Hager New Bi-directional RCBO
01.06: ABB Tmax MA and MF devices
01.06: ABB EMAX2 ACB 2I Protection setting for ARC Flash maintenance mode
01.06: ABB MCB SU200UC-Z DC
01.07: ABB MCB S400P
01.07: Legrand MCCB DPX HP
01.07: Legrand DX-H MCBs (Obs)
01.07: JEAN MULLER NH fuses links AC690V aR Size 2
01.07: Chint NXM-250S MCCBs
01.07: Chint NXBLE RCBOs
01.07: Schneider Electric Easy9 Breakers
01.07: Schneider Electric Acti9 Active AFDDs
01.07: Schneider Electric PowerLogic Relay
01.08: Proteus Bi-directional RCBOs
01.08: Eland H07RN-F AD8 EN 50525-2-21 Flexible Rubber Cable (CEI-UNEL 35026)
01.08: Eland cable 2XSLCYRY 0.6/1kV Cable
01.08: Eland NYY-J PVC 0.6/1kV Power Cable
01.08: BS6708 Type 21 Mining Cable
01.08: Doncaster Single-phase PVC Split Concentric BS 4553-1
01.08: Anord Mardix RESINBAR CXC Busbar