    See what's new in ElectricalOM v2024.05


    New functionality

    29.01: Street lighting columns auto creator



    30.01: Bunched cables option for grouping factor



    20.02: CAD plan: Hatch grid function for spaces



    20.04: Ability to update all lighting columns and fixture details of the same street lighting arrangement



    20.04: Ability to update all PV String panel properties of the same PV array



    20.04: Ability to set the position of the incomer SPD



    20.04: Cable Euro Class builder



    20.04: Ability to overwrite circuit impedances based on the test results (R1,R2)



    22.04: ZSI - Logic Selectivity (Generic option)



    25.04: Extended LV/LV transformer settings



    25.04: IT System 1st fault/RA max calculations and report for Signalling Power Systems



    25.04: Ability to define the L-N and L-E fault levels separetly on a 3-Phase system



    26.04: Gapped CPC option



    27.04: Simplified fault level settings as per the IET Guidance Note 3, Section 2.6.17, for the user defined 3-Phase supply



    29.04: Cables in fire: Apply the fire conditions when calculating earth faults



    10.05: Dwg export selected function for cad based cable schedules



    10.05: Auxiliary circuit equipment




    Improvements & Bug fixes

    08.01: Quick way to refresh the license from Help > About


    16.01: EC - Extra cable/core option. This will cover the requirement to use an extra core/cable, including the final and distribution circuits. This option has replaced the emergency lighting option.



    18.01: UK Forms: Setting to exclude the non-tested circuit details from the DB schedules



    25.01: Ability to include the sources in the Bill of Quantities report



    25.01: Show cable's installation method in schematic



    25.01: New DC Circuits section in the circuit details and Arc flash area



    29.01: Function to update all lighting column cables in the circuit editor



    29.01: Function to update all lighting fixture cables of the street lighting arrangement in the circuit editor



    11.02: New code "&f_isc_max_board" that can be used to display the maximum fault current in kA at the board when generating excel based reports



    11.02: New code "&f_supply_from" to display the supply from circuit



    11.02: New code "&f_db_ways" to display the board ways



    11.02: New code "&f_db_incoming_cable" to display the board's incoming cable



    11.02: New code "&f_db_spare_per" to display the board's spare way's percentage



    20.02: CAD plan spaces: ability to adjust the space text visibility



    01.03: Included stage and status options in the project info area



    20.04: Elements with warnings have different colour based on the warning type



    20.04: Auto cable ID from circuit details



    27.04: The earthing electrode resistance (Re) can be defined directly from the fault levels area when defining a TT system



    02.05: Consideration for reg. 522.8.10 for buried cables in ducts



    02.05: Extra cables in the meter tails selection and meter tails cable on main supply report



    02.05: Ability to update the inspection schedules outcome on an existing EIC/EICR from a MobileEOM file



    02.05: Maximum cable length for voltage drop is now included on the analytical calculations report



    10.05: Minimum phase fault at starting point is shown on the analytical reports and properties



    10.05: Omission of SWA for calculations option




    Devices

    08.01: EATON NZMLW-4 MCCB


    08.01: Proteus New MC MCCBs


    11.01: Proteus Devices Selectivity and Cascading tables


    16.01: Generic EV RCCBs EN 62955


    16.01: Scolmore Elucian Protective devices


    18.01: SE NSX breakers Cascading tables updates


    25.01: Vicfuses DC


    29.01: Chint RCBOs/AFDDs devices


    19.02: Legrand DMX3 ACBs


    01.03: Matt:e MCBs MTE/M 15-63 and RCBOs MTE/G 15


    01.03: Nader NDB1-63 MCBs


    01.03: Nader (DC) MCCBs NDB6AZ-63H, NDB6AZ-125H


    01.03: CBi DC MCBs


    01.03: CBi electric QF17 - Series Earth Leakage devices


    01.03: Starbreaker EN 61009 RCBOs and AFDDs


    24.04: Square D MCCBs PAF Range


    24.04: Ferraz Shawmut (HV) AMP-TRAP CS-3 Fuses



    Cables

    19.02: BS7870-4.10 Cu/XLPE/MDPE 19/33 (36)kV Graphite Black UV Resistant


    19.02: ÖLFLEX® ROBUST 200 & 215C cables


    19.02: AEI Firetec Enhanced cable


    20.04: Nexans IFSI-EMC 0.6/1KV Cu-screen


    20.04: TFKable cables supplier implementation


    20.04: Doncaster Cables supplier implementation



    02.05: Arctic Grade 3183AG Flex Cable BS 6004:2012 300/500V



    Busbars

    20.04: Busbar - MEGABARRE \ IMPACT²


    02.05: Schneider Electric I-LINE Track