10.01: Lighting inspection Devices list can be exported to excel
12.01: Ducts configuration for grouping
12.01: Add spares circuits function for switchboard elements
03.02: Conductor energy losses calculations and report
03.07: UK Forms - Ability to generate an email with the certificate/report details and pdf attachment ready for submission to the client
03.08: SPD can be defined at the incomer side of Distribution circuits
03.15: Insert Junction box in-between circuit function
03.15: Export to Excel of the UK Forms DB Schedule
03.22: CAD Plan: Ability to create a wiring section from an existing polyline figure
03.22: UK Forms: Ability to copy a value below in the Emergency Lights Devices list
03.22: Ability to define origin point for the voltage drops and to user define the max. voltage drop limit at each distrubution circuit
03.22: Ability to show the design current (Ib) on the selectivity study curves
03.22: New report to show the adjustable devices settings and the corresponding Max Zs
03.22: Ability to visualise the overcurrent and earth fault curves separately in the selectivity study
03.29: New selectivity study reports for overcurrent and earth fault protection only
04.05: Ability to overwrite the cable descriptions
18.05: Ability to insert and size solar inverters in an AC network
18.05: Renewable loads and voltage drop/rise calculations
18.05: Ability to define the Device ID and custom description
24.05: Grading Margins in Selectivity study
31.05: Prosumer setting at the main supply
10.01: Electric Vehicle Charging Equipment 3Ph and 3Ph+N option
18.01: Ability to define duct sizes upto 300mm
01.02: Revit sync improvements
02.02: Analytical report will indicate the calculation status
20.02: Bug fix: In UK forms 2 pages DB schedules not showing the other cable type
20.02: CAD plan now can auto create circuit after array symbol insertion
20.02: Ability to define separate cpc conductor of any size (1-1000mm²) when selecting the element conductor (Cu, Al)
20.02: Ability to show another photo in the details of the observation report, proving the rectification done
21.01: Ability to define earthing notes that will appear in the main supply report
01.03: Fixes when accessing the Revit families EOM properties when having non-powered electrical systems in the model
01.03: Extra ERA correction factors for cables installed in ground
02.03: Label size will now be applied on the untethered DB placeholder symbol
02.03: Bug fix: Arc flash study uses the correct device when setting the upstream device setting
08.03: Revit EOM family profiles will consider the family types when identifying the families used in the model
14.03: Star/Delta Motor improvements
14.03: 3m rule will be only considered when checking the option for overload device possition based on BS7671 Reg 433.2
14.03: Extra board label options to show the Voltage and Frequency
15.03: Revit eom parameters import will sync the native wire type and device rating parameters. The option needs to be checked first in the EOM export/import options in Revit
28.03: General notes of the circuit can be set from the circuit details area allowing multiple changes to the selected circuits
28.03: Arc flash calculations at the panel can be displayed in the DB label
01.04: Bug fix: The arc flash voltage was not displayed correctly on the reports
05.04: Ability to hide the fault level details of the main supply
06.04: Bug fix: Editing CAD plan imported symbol
07.04: Ability to export/import the cad plan design symbol library
18.05: UK forms certificates registry can be exported to excel
18.05: Breaking time consideration for Thermo-Magnetic MCCBs
18.05: Bug fix: PFC report not generated when the PFC was supplied from a busbar section
18.05: Re-organised "Other details" section in the circuit editor
18.05: Option to ignore selectivity warnings
18.05: When having an IT system the max Zs for the second fault is now based on BS7671:2018+A2 Reg: 411.6.5
18.05: Default working distance for Arc flash calculations
18.05: Ability to set the shock protection boundaries considering NFPA 70E, EN 50110-1 or user defined
18.05: Updated Arc Flash label
19.05: UK forms Minor works device Max Zs field and calculation
19.05: Interactive eom parameters update in Revit when applying changes in EOM
31.05: Measurement equipment resolution awareness when calculating the Test results Vs Calculated values
31.05: Improved multi-license interface
10.01: Siemens 3V1 MCCBs Backup Protection Tables
18.01: Siemens 5SY6 EN 60947-2 MCBs
18.01: Siemens 2VA MCCBs Backup Protection Tables with 5SY6 MCBs
18.01: RCBOs Acti9 C60 6kA 2P,3P,4P
18.01: Proteus Obsolete MCCB F51 250A
24.01: EATON PLS6 MCBs
24.01: EATON PKN6 RCBOs
24.01: EATON PFIM RCCBs
24.03: Schneider Acti9 C60 RCBOs 10kA/15kA 2P,3P,4P
31.01: WEG aR Class High Speed Fuses
03.02: Hager HW+ ACBs
20.02: Legrand DPX3 MCCBs Electronic, Thermomagneric 250-1600A
01.03: Manually operated Schneider Electric NS Micrologic MCCBs
02.03: Siemens 3WA SENTRON ACBs
28.03: Eaton Bussman DFJ Class J high speed fuses
28.03: Siemens MCCBs 3VA13 TM240, 3VA14 TM240 ATAM
05.04: Mitsubishi ACB AE630-SW 65kA to AE6300-SS 65kA
15.04: Conquer DC AXT fuses
15.04: Dornan Smith Loadline ACBs Z3 AGR-21BL-PG LSIG
18.05: Siemens 5SU1 RCBOs IEC 60947-2 15kA & 20kA
02.06: Terasaki Tembreak2 MCCB S800-NJ
15.06: Siemens 3VA TM MCCBs Vs 5SY7&8 MCBs Selectivity tables
10.01: NHXCH E30 and NHXCH E90 Life safety Cables
24.01: Chainflex® CF37.D Multicore Motor cable
24.01: Chainflex® CF300.UL.D Single-core cable
08.02: Revised tri-rated cable data
01.03: Prysmian FP500 Fire Resistant Control Cable
04.04: TOPFLEX-EMV-UV-3-PLUS-2XSLCH-J VFD Motor connection cable
04.04: ÖLFLEX® SERVO 2XSLCH-JB - Motor cable for drives with high electrical power
18.05: Cleveland Solar Energy Cable BS EN 50618
15.06: Draka IFSI-EMC PURE 1KV CU / AL Safetycable
20.02: GLS Busbars 25, 40, 63A