Thank You for
Choosing ElectricalOM
Designing and Maintaining Safe Electrical Installations
v2021.06 is Here
We have updated ElectricalOM to version 2021.06. This is the most heavily developed version, based on the many feature requests we have received from all our valuable users that have adopted ElectricalOM. In this version, we have made many improvements to existing fucntionality, to further enhance the software's ability to deal with any size and project complexity.
You can update the software by downloading and installing it directly from here:
https://electricalom.com/app/eom/download/
Warning
A. ElectricalOM Core
Equipment type functionality
The Equipment type functionality will help the user to organise and categorise specific loads and boards. This will enable to easily review and/or apply mass changes to common/typical boards, like typical boards in hotel rooms for example.
The setting can be defined in the "Other details" or in the Circuit Editor or at the Circuit Details under the Load category.
Each equipment type can have a description and a colour. The user can create any number of types and keep them organised in categories.
From the Functions menu, the user can perform several actions to help with productivity when modeling large and complex electrical installations.
1. Lookup
2. Mass changes
2.1 Clone ways
2.2 Clone Load density entries
2.3 Clone Predefined load values
Early-stage design functionality
2.1. Load densities
The load density option will consider the load density entries as the connected load to the panel. This functionality is useful for early-stage designs load estimations, where the actual equipment is not yet known.
2.2. Load density templates
From the Load density templates window, the user can select appropriate load densities from a list of predefined values based on recognised bodies. Furthermore, the user can create custom categories and density entries based on his/her experience. The list can be exported/imported in order to be shared with other colleagues.
2.3. Load densities are also available in circuit details for quick adjustments and selections.
If required the user can apply quick changes by multi-selecting load density entries using the circuit editor area. The advanced filtering functionality can help the user to quickly select the desired entries and apply specific changes.
2.4.A floor level based summary report can be generated to list all inputs across the floor levels defined
Colour scheme
The colouring functionality has been enchased to include the 3 cases below:
1. Colour groups: Colours based on the created colour group
2. Load type: Colours based on the the DBs load type (Sub circuits, Predefined, Load Density)
3. Equipment type: Colours based on the set Equipment type colour
Distribution boards labels
The user can now display information related to each distribution board from the board labels option. The labels are customised to list only the specific items selected. Also the abbreviations of the labels can be modified to reflect the design requirements.
Activate inactive circuits and close opened switch with double click
The user can now activate network elements and configure the active network path by double clicking on an inactive element or an opened switch.
Circuit Details include the trunking/conduit type/size
Changes to the trunkning and conduit sizes and type can be adjusted through the circuit details page, to enable quick inspections and multiple changes if necessary.
Description options
Extra options can be applied to the description of the final circuit for displaying the Watts and power factor defined.
Apply minimum cable sizes to the model
The user can now quickly apply the minimum cable sizes of the relevant circuit kinds directly from the Minimum Cable Sizes window, and update an existing model based on the selection. Please note that this is a global setting so it will be maintained in other projects too.
Templates Export/Import
The user can now export any implemented templates and import them to other PCs, enabling the ability to share the templates with other users.
Maximum allowed temperature of the conductor
The user can now specify a global setting that will be used to check the cable's operating temperature limit. This setting will not affect the current-carrying capacities like the Run to 70°C derating factor. Additionally, this setting can be specified locally for each circuit, from the circuit editor, in case a special case needs to be considered.
Auto cable ID numbering improvements
The auto cable ID environment has been improved in order to cover several cases, for auto defining cable IDs in the network.
Auto BTS section naming
A new functionality has been introduced to allow quick naming of the sections of the selected Busbar trunking system.
Action menu in the main menu area
The insertion menu has been replaced by the action menu similar to the tree network view and schematic's actions menus.
Tree network options to display cable sizes, devices etc
The tree network options can be used to display important information about each circuit listed in the tree network view, allowing quick inspection of the relevant input.
Cable display scheme (make-up, cable id, make-up + cable id) and predefined option
Extra options have been introduced for customising the cables' label. A global option can be defined for every new circuit as well as options for existing circuits via the schematic diagram properties area, the circuit editor and the circuit details area for multiple changes.
Board compacted mode symbols
With multi selection you can easily change the compacted mode boards' symbol.
Isolating transformer option and 2nd fault touch voltage checks
The transformer connection can be set to an Isolating Transforming implementing IT earthling system from that point and downstream. This functionality is required in specific industries (e.g. rails signaling) and in special locations (e.g. medical locations).
Further Enhancements:
Provision for BS 7671:2018 reg 419.2 and 419.3
Quick cpc selections: same as phase conductor size and based on table 54.7
Single-phase delta connection circuits (L1-L2, L2-L3, L3-L1)
Enhancements in motor settings (horsepower, motor starting power factor)
Drawing mode new function for inserting text
Bill of quantity selections in report selections
Show the way information when creating pages and untethering circuit
Default compacted mode option for distribution circuits
Direct links to knowledgebase and forum from the help menu
B. Reports:
New reports and enhancements in existing ones have been developed
Below is a list of new reports and enhancements included in the new version:
After Diversity Max. demand
Circuit schedule (Simple)
Harmonic assessment
IT system 2nd Fault Touch voltage
Load densities
Equipment types
CAD Plan symbols summary
Dual split boards are grouped at the boards' report
Watermark option from report selections
Excel templates functionality
Excel template reports will allow you to create custom report types based on Excel templates. The Excel templates contain codes that are replaced by ElectricalOM design parameters and calculation results. In order to create custom codes for specific requirements and report structure please contact us.
C. Revit Sync add-on
The improvements and the new functionality updates in the ElectricalOM Revit Sync add-on are listed below:
Revit 2022 compatibility
Assign spaces to panel boards
Sync spaces with EOM load density records per board
Spaces descriptions in each final load and area description for distribution circuits
Considerations for dual split board design
Option to sync panel boards based on common names
General improvements in the sync process
D. CAD Plan design add-on
The improvements and new functionality updates in the ElectricalOM CAD Plan design add-on are listed below:
Cad plan symbol summary in reports
Symbols summary count in CAD per layer/floor level
Improvements in Plan 3D environment
2D flatten option of a binded xref drawing
Fix dimension option when scaling binded xref drawings
Insert vertex in a polyline or a wiring section from right click menu
E. UK Forms add-on:
The improvements and new functionality updates in the UK Forms add-on are listed below:
New certificates for Emergency lighting and Fire alarms (Beta)
Submit test results from Minor works certificates
Certificates registry
Extra settings to customise the distribution board schedules
Convert EIC to EICR or vice versa
EICR rectify observations and generate a satisfactory report
Observation lists with photos
Circuit not tested option
Option to show max Zs at 80% on the test schedules
Fill report sections from MobileEOM app
Import test results from MobileEom file directly in a certificate, all DBs or a selected DB
MobileEOM app new version
F. Protective Devices and cables library
We are constantly updating and improving the software's libary based on the users requirements. Below are some of the new additions included in the new version:
Cables:
Eland category to list Eland cables with the relevant technical information
Network Rail cables: TRATOS-RAILWAYS Signalling Power Distribution Cable
TYPE CY PVC CONTROL CABLES
NSSOEU Cable
DALI 5 core Lighting cable
AFUMEX
RADAFLEX A Power Cable
Draka Railsure Single Core Zero Halogen, Low Smoke
NKT TFL DC cables
And many more based on users' requests
Protective devices:
Schneider Asia CVS devices
Schneider TeSys GV5, TeSys GV6 and TeSys GV7
Schneider Compact NSX Micrologic 4 and Compact NSX Micrologic 7
SIEMENS SIRIUS Compact starter, 3RV1 and 3RV2 Motor Protection
SIEMENS LV Sitor Fuses
SIEMENS DIAZED Fuses
SIEMENS Neozed Fuse links
Terasaki Tembreak 2 MCCBs XS2000-NE, XS2500-NE and XS3200-NE
British General Electrical devices
Bitcino devices
Obsolete Merlin Gerin devices
Littefuses (DC)
Mersen PV fuses (DC)
And many additions as per users' requests and improvements in the existing equipment