Announcements

ElectricalOM Update 2019.06.13

 Thursday, June 13, 2019


Thank You for

Choosing ElectricalOM

Designing Safe Electrical Installations, together.



v2019.06.13 is Here


We have updated ElectricalOM to version 2019.06.13. In this version, we have made many improvements and we implemented new features based on users requests and feedback. To update the software, run it and choose "Download the new version" from the pop-up message (See the Knowledgebase). Alternatively, you can download the new version directly from here: ElectricalOM 2019.06.13.01.


Warning

Download the new version only if you have an active support/updates subscription. To renew your support/updates subscription please contact us.


What's new?



1. Core package

Native Earth Fault Adjustable Settings

We have included the native manufacturers' specific earth fault adjustable settings. The settings can be defined and adjusted like any overcurrent setting either during the protective device selection and/or during the selectivity study.

Ground fault settings


Power factor for short-circuits on LV sources

The Power factor for short-circuits on Low Voltage sources can be determined using Table 11 in standard IEC 60947-2 which specifies the test conditions used to determine circuit-breaker breaking capacities.
Power factor for short-circuits on LV sources

Cable in Paging Placeholders

When creating new pages in the schematic will now include the cable of the distribution circuit taken to the new page, making it easy to see the cable details without the need to navigate to the new page.

Placeholders show the cable


Extra fields in Schematic Cable Schedules

In the new version, we have included two extra fields in the Schematic Cable Schedules for including the Installation Method and the Protective Device of the circuits.

Schematic cable schedules

Expandable Opened Project

You can now expand a project page by double-clicking on the project's tab page. This will enable you to have open projects in multiple screens to easily review and exchange data between them.

Expand project Page


Protective Devices Commissioning Report

A new report is included in the reports list for listing all protective devices used in the project with relevant settings and selectivity study related calculations, which can be used for project commissioning.

Protective devices commissioning report

New Circuit Kinds

In the circuits kind list, we included the 'Fire Alarm' and the 'Fixed device - General' option.

New circuit kinds


Improved Interface for Installing Supply Connections


The improved interface during the installation of a new supply connection will enable you to choose the DB's way of the supply connection and also allow you to interact with the schematic for zooming and panning.

Supply connection



2. CAD Plan Design Add-on


Extra Symbols and a New Fire Alarm Category

We have included extra symbols in all symbol categories and a new category for Fire Alarm systems.

fire alarm cad symbols

 Symbols Legend Functions

We have introduced two functions of the symbols' legend for quick remove and for quick find in the drawing.
cad legend


Scale Symbols During Import

In the new version, we included the option to auto-scale the symbols imported from an external dwg file.
scale symbols



3. Autodesk Revit Add-on

Revit 2020 Compatibility and Performance Improvements

In the new version, we are supporting the new Revit 2020 and we have improved the synchronization performance between ElectricalOM and Revit.
Revit 2020


4. New Protective Devices

Terasaki

  • Tembreak 2 E160-SF
  • Tembreak 2 S800-RE
  • Tembreak 2 S1000-SE
  • Tembreak 2 S1000-NE
  • Tembreak 2 S1250-SE
  • Tembreak 2 S1250-NE
  • Tembreak 2 S1250-GE
  • TemPower ACB AT32

Schnieder

  • Masterpact ACB Micrologic NW32 H1 2.0
  • Masterpact ACB Micrologic NW32 H1 5.0
  • Masterpact ACB Micrologic NW32 H1 6.0
  • Masterpact ACB Micrologic NW32 H1 7.0



5. Busbar Trunking Systems

  • Legrand Zucchini 2018
    • MS - Cu (Cas.)
    • MR - Cu (Cas.)
    • MR - Al (Cas.) (Ue 1000V)
    • MR - Cu (Cas. + Int.)
    • MR - Al (Cas. + Int.) (Ue 1000V)
    • MR - Al (Cas.) (Ue 690V)
    • MR - Al (Cas. + Int.) (Ue 690V)
    • LB PLUS - Type A - Cu (Cas.)
    • LB PLUS - Type B - Cu (Cas.)
    • SCP - Al(3L+N+PE) (Single Bar)
    • SCP - Al(3L+N+PE) (extra Cu) (Single Bar)
    • SCP - Al(3L+N+PE) (extra Al) (Double Bar)
    • SCP - Cu(3L+N+PE) (Single Bar)
    • SCP - Cu(3L+N+PE) (extra Cu) (Single Bar)
    • SCP - Cu(3L+N+PE) (extra Al) (Single Bar)
    • SCP - Al(3L+N+PE+FE) (Single Bar)
    • SCP - Al(3L+N+PE+FE) (extra Cu) (Single Bar)
    • SCP - Al(3L+N+PE+FE) (extra Al) (Single Bar)
    • SCP - Cu(3L+N+PE+FE) (Single Bar)
    • SCP - Cu(3L+N+PE+FE) (extra Cu) (Single Bar)
    • SCP - Cu(3L+N+PE+FE) (extra Al) (Single Bar)
    • SCP - Al(3L+2N+PE) (Single Bar)
    • SCP - Al(3L+2N+PE) (extra Cu) (Single Bar)
    • SCP - Al(3L+2N+PE) (extra Al) (Single Bar)
    • SCP - Cu(3L+2N+PE) (Single Bar)
    • SCP - Cu(3L+2N+PE) (extra Cu) (Single Bar)
    • SCP - Cu(3L+2N+PE) (extra Al) (Single Bar)
    • SCP - Al(3L+N+PE) (Double Bar)
    • SCP - Al(3L+N+PE) (extra Cu) (Double Bar)
    • SCP - Al(3L+N+PE) (extra Al) (Single Bar)
    • SCP - Cu(3L+N+PE) (Double Bar)
    • SCP - Cu(3L+N+PE) (extra Cu) (Double Bar)
    • SCP - Cu(3L+N+PE) (extra Al) (Double Bar)
    • SCP - Al(3L+N+PE+FE) (Double Bar)
    • SCP - Al(3L+N+PE+FE) (extra Cu) (Double Bar)
    • SCP - Al(3L+N+PE+FE) (extra Al) (Double Bar)
    • SCP - Cu(3L+N+PE+FE) (Double Bar)
    • SCP - Cu(3L+N+PE+FE) (extra Cu) (Double Bar)
    • SCP - Cu(3L+N+PE+FE) (extra Al) (Double Bar)
    • SCP - Al(3L+2N+PE) (Double Bar)
    • SCP - Al(3L+2N+PE) (extra Cu) (Double Bar)
    • SCP - Al(3L+2N+PE) (extra Al) (Double Bar)
    • SCP - Cu(3L+2N+PE) (Double Bar)
    • SCP - Cu(3L+2N+PE) (extra Cu) (Double Bar)
    • SCP - Cu(3L+2N+PE) (extra Al) (Double Bar)




« Back