Example Details
In this tutorial we will design a three phase domestic installation. The installation consists of three distribution circuits, the Main Distribution Board and two sub distribution boards. The Main Distribution Board is located at the ground floor and feeds a sub distribution board to the basement and another to the floor level. The basic information required for the design are the Main Supply characteristics and the final circuits per distribution board. These are presented below:
Main supply characteristics:
Type: Three phase - Public supply
Voltage: 400V/230V, 50Hz
Earthing system: TN-C-S
Source rating: 500kVA with source impedance Z: 6%
Supply cable up to the origin of the installation:
- Up to the building: Al - Multicore XLPE 90oC armoured, length: 20m, cross sectional area: 16mm2, installed underground
- Up to the meter: Al - Multicore XLPE 90oC armoured, length: 10m, cross sectional area: 16mm2, installed on a surface
Distribution circuits:
Name |
Supplied from |
Phase |
Cable length (m) |
Cable type and installation method |
Main: MDB |
Main supply |
Three phase |
5 |
Cu - Multicore XLPE 90oC armoured, in underground single way ducts |
Basement DB-G |
MDB |
Single phase |
10 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Floor level DB-F |
MDB |
Single phase |
10 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Main Distribution Board - MDB:
load kind |
Installation points |
Cable length (m) |
Cable type and installation method |
Cooker |
1 |
15 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Dish washer |
1 |
10 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Dryer |
1 |
10 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Fridge |
1 |
10 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Air conditioning 1 |
1 |
20 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Air conditioning 2 |
1 |
20 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Sockets ring |
25 |
45 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Lights 1 |
15 |
30 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Lights 2 |
15 |
25 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Basement distribution board- DB-G:
load kind |
Installation points |
Cable length (m) |
Cable type and installation method |
Fridge |
1 |
10 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Air conditioning |
1 |
20 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Sockets ring |
15 |
30 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Lights 1 |
10 |
25 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Lights 2 |
15 |
30 |
Cu - Single Core PVC 70oC non-armoured, in conduit in a wall |
Floor level distribution board- DB-F:
load kind |
Installation points |
Cable length (m) |
Cable type and installation method |
Air conditioning 1 |
1 |
15 |
Single Core PVC 70oC non-armoured, in conduit in a wall |
Air conditioning 2 |
1 |
15 |
Single Core PVC 70oC non-armoured, in conduit in a wall |
Sockets ring |
15 |
30 |
Single Core PVC 70oC non-armoured, in conduit in a wall |
Lights 1 |
10 |
25 |
Single Core PVC 70oC non-armoured, in conduit in a wall |